    MARSH is a private reefing group. Comments and suggestions are encouraged, but please keep them positive and constructive. Negative threads, posts, or attacks will be removed from view and reviewed by the staff. Continually disruptive, argumentative, or flagrant rule breakers may be suspended or banned.

Aquarium Grounding (1 Viewer)

Users who are viewing this thread

Tangs

Guest
Joined
Apr 27, 2008
Messages
2,009
Reaction score
425
Location
Sarnia, Ontario
Hey. I guess it was in the late 90s as a wild guess I decided to ground my aquarium. I just got a wire into the 125 and brought it down to the basement where I wrapped it around copper plumbing. Question is.... If I have a modern plug socket can I just attach the wire to the center plate screw. The screw that holds the exterior cover on the plug outlet. Will that give me a ground rather than tempting fate every time I put my hand in the water. Ya
 
OP
OP
Tangs

Tangs

Guest
Joined
Apr 27, 2008
Messages
2,009
Reaction score
425
Location
Sarnia, Ontario
Ok I found titanium grounding PROBE on Amazon.com. I can get what we call GFI from home Depot in town. I already got lots in my house. Thanks.
 
Joined
Feb 4, 2014
Messages
10,899
Reaction score
2,066
Location
League City
What does the grounding probe do that the GFCI won’t do. The GFCI should cut power right.

I ran across a thread like this a while back. I can’t remember why it was better or good to have the grounding probe.
 

foos

Supporting Member
Build Thread Contributor
Joined
Apr 25, 2018
Messages
505
Reaction score
644
Location
Katy, TX
What does the grounding probe do that the GFCI won’t do. The GFCI should cut power right.

I ran across a thread like this a while back. I can’t remember why it was better or good to have the grounding probe.
GFCI trips when the current on the two wires does not match. If you take a bucket of salt water and shove a smashed heater in it that is only two wire, or where the ground is not exposed, the GFCI will not trip and the current running through the salt water will create some nasty things like bleach. The ground probe gives the electricity of a broken heater/pump/what have you a different path so that the GFCI can detect it and trip.

When using GFCI remember that something in your tank will eventually break and the GFCI will trip turning off everything on it. I like to split things like heaters between two GFCI so that if one trips there is still enough stuff running to keep the tank alive. I also have alarms and notifications set up for when that happens.
 

steveb

Staff member
Administrator
Moderator
Board Member
Build Thread Contributor
Joined
Jun 24, 2009
Messages
11,953
Reaction score
2,856
Location
Spring
GFCI trips when the current on the two wires does not match. If you take a bucket of salt water and shove a smashed heater in it that is only two wire, or where the ground is not exposed, the GFCI will not trip and the current running through the salt water will create some nasty things like bleach. The ground probe gives the electricity of a broken heater/pump/what have you a different path so that the GFCI can detect it and trip.

When using GFCI remember that something in your tank will eventually break and the GFCI will trip turning off everything on it. I like to split things like heaters between two GFCI so that if one trips there is still enough stuff running to keep the tank alive. I also have alarms and notifications set up for when that happens.

Chris I agree ..and that is exactly what happened to me. heater ruptured. When I was wearing rubber soled shoes I didn't notice it (think bird on a high voltage wire). When I went out there barefoot and happened to stick my hand in the tank - whamo - I became the earth ground path. When that happened it did trip the GFCI but still a very unpleasant experience (had a grounding probe been in the water tied to the GFCI it would have tripped before I became the ground path).

@Tangs Had there been no GFCI then the likely outcome would have been a much worse situation. You CANNOT rely on an earth ground to save you. It is not designed for that.
 

mittens

Supporting Member
Member Spotlight Contest Winner
Joined
Apr 23, 2017
Messages
985
Reaction score
926
I had 3 that were a little used. But they aren’t fs since I threw them away.
 
OP
OP
Tangs

Tangs

Guest
Joined
Apr 27, 2008
Messages
2,009
Reaction score
425
Location
Sarnia, Ontario
I have 4 outlets behind my 125. I got 3 of then installed in 07.. I can get that down to 3 being used because I am using an exterior extension cord. Makes it easier to plug and unplug some things...Plan is to get one titanium grounding probe. 3 gfi's. Onward and forward.
 

soymilk

Supporting Member
Joined
Feb 3, 2010
Messages
2,611
Reaction score
1,358
Location
Fresno, Texas
i have a gfi in the kitchen that will trip every now and then on my little qt tank. is it a warning sign my brand new heater is going out then?
 
OP
OP
Tangs

Tangs

Guest
Joined
Apr 27, 2008
Messages
2,009
Reaction score
425
Location
Sarnia, Ontario
I have had a few heaters crack in the tank over the years. Around 2002 ish my water had an electrical charge in it for a few days. No livestock died but was a nasty shock for sure. I think it was from lighting.
 

foos

Supporting Member
Build Thread Contributor
Joined
Apr 25, 2018
Messages
505
Reaction score
644
Location
Katy, TX
i have a gfi in the kitchen that will trip every now and then on my little qt tank. is it a warning sign my brand new heater is going out then?
Maybe, maybe not. They are a safety device and designed to trip before you get electrocuted if you are where the stray current is going. Doesn't take much to kill a person so they can be rather sensitive. They are also designed to get more sensitive over time instead of less so they should never allow enough through to kill you.

I did have one that kept randomly tripping like once a month at 2 am.... eventually found a heater with a tiny bit if rust inside it. Stopped tripping after I removed that heater.
 
Joined
Feb 4, 2014
Messages
10,899
Reaction score
2,066
Location
League City
Maybe, maybe not. They are a safety device and designed to trip before you get electrocuted if you are where the stray current is going. Doesn't take much to kill a person so they can be rather sensitive. They are also designed to get more sensitive over time instead of less so they should never allow enough through to kill you.

I did have one that kept randomly tripping like once a month at 2 am.... eventually found a heater with a tiny bit if rust inside it. Stopped tripping after I removed that heater.
I also heard they trip if you have too much plugged into that outlet.
 

RickD

Guest
Joined
Dec 26, 2004
Messages
314
Reaction score
38
Location
Friendswood
Chris I agree ..and that is exactly what happened to me. heater ruptured. When I was wearing rubber soled shoes I didn't notice it (think bird on a high voltage wire). When I went out there barefoot and happened to stick my hand in the tank - whamo - I became the earth ground path. When that happened it did trip the GFCI but still a very unpleasant experience (had a grounding probe been in the water tied to the GFCI it would have tripped before I became the ground path).

@Tangs Had there been no GFCI then the likely outcome would have been a much worse situation. You CANNOT rely on an earth ground to save you. It is not designed for that.
Same thing happened to me a week ago. I typically have towels on the ground to catch any spills, but this time I did not. I was shortest path to ground. My GFCI never tripped, but I got a nice jolt. I checked the stray current with my multimeter and pulled a plug one at a time - it was my heater. I've since put a grounding probe and portable GFCI. Also there is induced voltage from your wavemakers and pumps. I was measuring around 24V, which is different from stray current. With the grounding probe I'm measuring Zero.
 

foos

Supporting Member
Build Thread Contributor
Joined
Apr 25, 2018
Messages
505
Reaction score
644
Location
Katy, TX
Same thing happened to me a week ago. I typically have towels on the ground to catch any spills, but this time I did not. I was shortest path to ground. My GFCI never tripped, but I got a nice jolt. I checked the stray current with my multimeter and pulled a plug one at a time - it was my heater. I've since put a grounding probe and portable GFCI. Also there is induced voltage from your wavemakers and pumps. I was measuring around 24V, which is different from stray current. With the grounding probe I'm measuring Zero.
It is important to know that they do not prevent you from being zapped, they cut off the zap before it is bad enough to kill you. It is also important to know that the test button is on them for a reason, they can get stuck and not trip. You are supposed to test monthly but I have never met a person that does that... I did like to test them as a kid, but I don't think "Oh neat! Buttons! click click click click click click click click click click click click click click click click click click" counts as testing.

There is also the chance you were not grounded well enough for enough current to flow through you to trip a GFCI, but a grounding probe near the heaters would have.
 
OP
OP
Tangs

Tangs

Guest
Joined
Apr 27, 2008
Messages
2,009
Reaction score
425
Location
Sarnia, Ontario
Just placed my order for a Rio titanium ground probe on amazon.com. we have Amazon.ca but lot more pricier..even with exchange and shipping.
 