    MARSH is a private reefing group. Comments and suggestions are encouraged, but please keep them positive and constructive. Negative threads, posts, or attacks will be removed from view and reviewed by the staff. Continually disruptive, argumentative, or flagrant rule breakers may be suspended or banned.

Apex code (1 Viewer)

Users who are viewing this thread

tmgrash

Guest
Joined
Oct 17, 2009
Messages
770
Reaction score
0
Location
League City
Someone mentioned to have a thread with different apex codes, here's mine. Still have more I want to do but this is a start.

Dosing Pumps

Alk
Fallback OFF
OSC 000:00/008:35/051:25 Then ON
If pH > 08.50 Then OFF

Cal
Fallback OFF
OSC 000:00/008:35/051:25 Then ON

Cooling Fan

Fallback OFF
If Temp > 81.5 Then ON
If Temp < 81.4 Then OFF


ATO, this is controlling the solenoid to allow water through the rodi which has double float switch in the sump.

Fallback OFF
Set OFF
If Time 17:30 to 17:50 Then ON
If Time 10:00 to 10:20 Then ON


Refuge Light

Fallback OFF
Set OFF
If Time 20:00 to 08:00 Then ON

Return

Fallback ON
Set ON


Blue Led

Fallback OFF
Set OFF
If Moon 000/000 Then MoonInt
If Time 08:00 to 12:00 Then RampUp
If Time 12:00 to 18:30 Then ON
If Time 18:30 to 21:00 Then RampDnB

MoonInt
Ramp time 1 min
Start intensity 0
End intensity 3

RampUp
Ramp time 240 mins
Start intensity 0
End intensity 100

RampDnB
Ramp time 150 mins
start intensity 100
end intensity 0

White Led


Fallback OFF
Set OFF
If Time 08:00 to 12:00 Then RampUp
If Time 12:00 to 15:30 Then ON
If Time 15:30 to 18:30 Then RampDnV
If Time 18:30 to 21:00 Then RampDnW


RampDnV
Ramp time 180
start intensity 100
end intensity 45

RampDnW
Ramp time 150
start intensity 45
end intensity 0


Email Alarm/ text alarm

Set OFF
If Temp > 83.5 Then ON
If Temp < 75.0 Then ON
If pH > 08.50 Then ON
[/b]
 

R-BallJunkie

Supporting Member
Joined
Aug 2, 2006
Messages
1,521
Reaction score
229
Location
Latitude N 8° 43' Longitude E 167° 44' , RMI
thanks,

im definately cutting and pasting a couple of these.

i want to have my skimmer turn off if my main pump is off so it doesnt overflow when my level rises in my sump.


i know this sounds trivial, but its kicking my butt getting the language right, coupled with lack of time the last two days.
 
OP
OP
T

tmgrash

Guest
Joined
Oct 17, 2009
Messages
770
Reaction score
0
Location
League City
R-BallJunkie said:
thanks,

im definately cutting and pasting a couple of these.

i want to have my skimmer turn off if my main pump is off so it doesnt overflow when my level rises in my sump.


i know this sounds trivial, but its kicking my butt getting the language right, coupled with lack of time the last two days.

You could create a profile for that, or more simply plug them both into the same outlet. Thats actually how I have mine. Saves you space on an outlet as well.
 

RR-MAN

Guest
Joined
Aug 18, 2003
Messages
5,689
Reaction score
1,214
Location
Pearland
Travis, thanks for the great info.

I ordered my Apex today...woooohoooo
 

soymilk

Supporting Member
Joined
Feb 3, 2010
Messages
2,608
Reaction score
1,344
Location
Fresno, Texas
I usually had a delay on my skimmer if the power went out. Because after turning off the return pump the water level in my sump always grew 2-3 inches. This caused my skimmer to overflow.

Travis,
Im gonna start a thread in equipment to catalog programs. I hope you don't mind me sticking them in there.
 

R-BallJunkie

Supporting Member
Joined
Aug 2, 2006
Messages
1,521
Reaction score
229
Location
Latitude N 8° 43' Longitude E 167° 44' , RMI
tmgrash said:
R-BallJunkie said:
thanks,

im definately cutting and pasting a couple of these.

i want to have my skimmer turn off if my main pump is off so it doesnt overflow when my level rises in my sump.


i know this sounds trivial, but its kicking my butt getting the language right, coupled with lack of time the last two days.

You could create a profile for that, or more simply plug them both into the same outlet. Thats actually how I have mine. Saves you space on an outlet as well.
D a m n,
i hate when i miss the obvious. cant think of a single scenario when you would need to run your skimmer w/o your main pump. now what to do with the freed up outlet, muh ha ha ha.

0.0
 
OP
OP
T

tmgrash

Guest
Joined
Oct 17, 2009
Messages
770
Reaction score
0
Location
League City
R-BallJunkie said:
tmgrash said:
R-BallJunkie said:
thanks,

im definately cutting and pasting a couple of these.

i want to have my skimmer turn off if my main pump is off so it doesnt overflow when my level rises in my sump.


i know this sounds trivial, but its kicking my butt getting the language right, coupled with lack of time the last two days.

You could create a profile for that, or more simply plug them both into the same outlet. Thats actually how I have mine. Saves you space on an outlet as well.
D a m n,
i hate when i miss the obvious. cant think of a single scenario when you would need to run your skimmer w/o your main pump. now what to do with the freed up outlet, muh ha ha ha.

0.0

Haha, I have had plenty of those with the apex. There is so much that can be done with this thing. I havent even used, yet, any delays, defers, DOW. I plan on getting auto feeder, water on floor sensor, wiring my ato float switch to apex, wxm, auto water change, room temp, salinity monitor/adjust, change my car oil, sweep the floor, mow the yard, ok well maybe some of those are a stretch. lol
 
OP
OP
T

tmgrash

Guest
Joined
Oct 17, 2009
Messages
770
Reaction score
0
Location
League City
soymilk said:
I usually had a delay on my skimmer if the power went out. Because after turning off the return pump the water level in my sump always grew 2-3 inches. This caused my skimmer to overflow.

Travis,
Im gonna start a thread in equipment to catalog programs. I hope you don't mind me sticking them in there.

no problem.
 

Mark L.

Moved On
Joined
Oct 8, 2010
Messages
7,532
Reaction score
0
Location
The Woodlands
Apex Programs

This is my setup so far. Pretty basic since I've been so busy. I figured out my lights and that's about it. It would be cool if we could have an Apex forum. Then each thread could be dedicated to a specific type of equipment. Lighting, Dosing pumps, Heaters, Protein Skimmers, etc. It would be an easy way too keep track of all the different programs people come up with for the given equipment. Just a thought.

Outlet Setups

SunRamp_I1 - (base Var1)
Control Type: Advanced
Icon: Up/Down Arrows
Set OFF
If Time 12:00 to 13:00 Then RampUp
If Time 13:00 to 19:00 Then ON
If Time 19:00 to 20:00 Then RampDwn

MoonRamp_I2 - (base Var2)
Control Type: Advanced
Icon: Up/Down Arrows
Set OFF
If Time 11:00 to 12:00 Then RampUp
If Time 12:00 to 20:00 Then ON
If Time 20:00 to 21:00 Then RampDwn

EmailAlm_I5 - (base email)
Control Type: Advanced
Icon: Email
Set OFF
If Temp > 84.0 Then ON
If Temp < 75.0 Then ON

FugLight_1_1 - (3-1)
Control Type: Light
Icon: LightB
Fallback (On/Off): On
On time (HH:MM): 19:00
Off time (HH:MM): 06:00
Shutdown probe (Probe Name): Temp
Device shutdown value (Probe Value): 84.0
Hysteresis (MMM:SS) 001:00

MainPump_1_2 - (3_2)
Control Type: Advanced
Icon: Spiget
Fallback ON
Set ON

LightFan_1_3 - (3_3)
Control Type: Light
Icon: Fan
Fallback (On/Off): Off
On time (HH:MM): 11:00
Off time (HH:MM): 21:15
Shutdown probe (Probe Name): Temp
Device shutdown value (Probe Value): 84.0
Hysteresis (MMM:SS): 005:00

SunLight_1_4 - (3_4)
Control Type: Light
Icon: Sun
Fallback (On/Off): On
On time (HH:MM): 12:00
Off time (HH:MM): 20:00
Shutdown probe (Probe Name): Temp
Device shutdown value (Probe Value): 84.0
Hysteresis (MMM:SS): 005:00

MP40Mstr_1_5 - (3_5)
Control Type: Advanced
Icon: Spiget
Fallback On
Set On

ATO_1_6 - (3_6)
Control Type: Advanced
Icon: Spiget
Fallback On
Set On

Empty_1_7 - (3_7)
Control Type: Advanced
Icon: Left/Right Arrows
Fallback Off
Set Off

MoonLight_1_8 - (3_8)
Control Type: Light
Icon: Moon
Fallback (On/Off): On
On time (HH:MM): 11:00
Off time (HH:MM): 21:00
Shutdown probe (Probe Name): Temp
Device shutdown value (Probe Value): 84.0
Hysteresis (MMM:SS): 005:00

MP40Slv_2_1 - (4_1)
Control Type: Advanced
Icon: Spiget
Fallback On
Set On

Heater_2_2 - (4_2)
Control Type: Heater
Icon: Thermometer
Fallback (On/Off): Off
Probe Name: Temp
On temperature: 77.0
Off Temperature: 78.0
Empty_2_3 - (4_3)
Control Type: Advanced
Icon: Left/Right Arrows
Fallback Off
Set Off

Calcium_2_4 - (4_4)
Control Type: Advanced
Icon: Spiget
Fallback Off
Set Off
If Time 21:00 to 21:01 Then On

Network_2_5 - (4_5)
Control Type: Advanced
Icon: Left/Right Arrows
Fallback On
Set On

Skimmer_2_6 - (4_6)
Control Type: Advanced
Icon: Spiget
Fallback On
Set On

Reactors_2_7 - (4_7)
Control Type: Advanced
Icon: Spiget
Fallback On
Set On

Alk_2_8 - (4_8)
Control Type: Advanced
Icon: Spiget
Fallback OFF
OSC 000:00/002:30/057:30 Then ON
If pH > 08.50 Then OFF

Profiles Setup

RampUp (PF1)
Control Type: Ramp
Ramp time (minutes): 60
Start intensity: 0
End intensity: 100

RampDwn (PF2)
Control Type: Ramp
Ramp time (minutes): 60
Start intensity: 100
End intensity: 0
 
R

RocketSurgeon

Bad_LS1 said:
This is my setup so far. Pretty basic since I've been so busy. I figured out my lights and that's about it. It would be cool if we could have an Apex forum. Then each thread could be dedicated to a specific type of equipment. Lighting, Dosing pumps, Heaters, Protein Skimmers, etc. It would be an easy way too keep track of all the different programs people come up with for the given equipment. Just a thought.
....

In the meantime, you could add something to the subject line. This would help when doing searches to find it later.
 

Mark L.

Moved On
Joined
Oct 8, 2010
Messages
7,532
Reaction score
0
Location
The Woodlands
RocketSurgeon said:
Bad_LS1 said:
This is my setup so far. Pretty basic since I've been so busy. I figured out my lights and that's about it. It would be cool if we could have an Apex forum. Then each thread could be dedicated to a specific type of equipment. Lighting, Dosing pumps, Heaters, Protein Skimmers, etc. It would be an easy way too keep track of all the different programs people come up with for the given equipment. Just a thought.
....

In the meantime, you could add something to the subject line. This would help when doing searches to find it later.

Good call. I just edited mine to add "Apex Programs" since it's a list of all of mine.
 

soymilk

Supporting Member
Joined
Feb 3, 2010
Messages
2,608
Reaction score
1,344
Location
Fresno, Texas
i've been lazy about the apex thread. I'll work on it tonight at work.

What do you guys think? Should I break it down to the users or should i break it down to the actual components? Like ato, lights, blah blah blah.
 

Mark L.

Moved On
Joined
Oct 8, 2010
Messages
7,532
Reaction score
0
Location
The Woodlands
I'd say by component. After some time we will end up with multiple programs for each component since everyone may want something a little different to suit their tank.
 

TexanReef

Guest
Joined
Nov 30, 2010
Messages
627
Reaction score
0
Location
290 at 6
Upgrade
Control Type: Advanced
Icon: Laugh
Fallback On
On newVersionReleased
Sell oldVersionCheapToScott

Someone add this to their program...

:D

Really, really looking forward to the Jr. being released in quantity.
 
OP
OP
T

tmgrash

Guest
Joined
Oct 17, 2009
Messages
770
Reaction score
0
Location
League City
Alk Dosing pump

Had to update my alk dosing pump due to the higher temps causing higher pH. So here is another option.


Fallback OFF
OSC 000:00/011:35/048:25 Then ON
If pH > 08.50 Then OFF
If Time 13:00 to 21:00 Then OFF
 

Mark L.

Moved On
Joined
Oct 8, 2010
Messages
7,532
Reaction score
0
Location
The Woodlands
Re: Alk Dosing pump

tmgrash said:
Had to update my alk dosing pump due to the higher temps causing higher pH. So here is another option.


Fallback OFF
OSC 000:00/011:35/048:25 Then ON
If pH > 08.50 Then OFF
If Time 13:00 to 21:00 Then OFF

Dang it. I need to spread my dosing over a few hour period using the OSC command. I'm just dripping for 30 minutes straight. I keep forgetting. I could do 3 minutes an hour for 10 hours. Say 9pm - 7am.
 
Top