not to intimidate you, i really do like to tinker when it comes to these things. but here's my configuration:
Left Pump |||||| Right Pump
---------------- |||||| ----------------
Fallback ON |||||| Fallback ON
Set OFF |||||| Set OFF
If Time 00:00 to 02:00 Then CrestM |||||| If Time 00:00 to 02:00 Then LowF
If Time 02:00 to 04:00 Then 4Sec |||||| If Time 02:00 to 04:00 Then 5Sec
If Time 04:00 to 06:00 Then WaveM |||||| If Time 04:00 to 06:00 Then WaveF
If Time 06:00 to 08:31 Then ON |||||| If Time 06:00 to 08:31 Then LowF
If Time 08:31 to 08:33 Then FeedP |||||| If Time 08:31 to 08:33 Then FeedP
If Time 08:33 to 11:01 Then WaveM |||||| If Time 08:33 to 11:01 Then WaveM
If Time 11:01 to 11:03 Then FeedP |||||| If Time 11:01 to 11:03 Then FeedP
If Time 11:03 to 12:56 Then CrestM |||||| If Time 11:03 to 12:56 Then CrestF
If Time 12:56 to 12:58 Then FeedP |||||| If Time 12:56 to 12:58 Then FeedP
If Time 12:58 to 15:30 Then ON |||||| If Time 12:58 to 15:31 Then ON
If Time 15:31 to 15:33 Then FeedP |||||| If Time 15:31 to 15:33 Then FeedP
If Time 15:33 to 17:00 Then WaveF |||||| If Time 15:33 to 17:00 Then WaveM
If Time 17:00 to 18:30 Then CrestM |||||| If Time 17:00 to 18:30 Then CrestM
If Time 18:30 to 20:00 Then WaveM |||||| If Time 18:30 to 20:00 Then WaveF
If Time 20:00 to 21:30 Then 5Sec |||||| If Time 20:00 to 21:30 Then 4Sec
If Time 21:30 to 24:00 Then LowM |||||| If Time 21:30 to 24:00 Then CrestF
The notation of M/F denotes Male/Female for whether it starts strong, then drops low, or low then strong
Wave is configured for on 8sec, off 4 sec(no ramping at all), from 0%->100%
Crest is on 5, off 1 sec. ramping from 60%-100%
Low is on 5, off 5. ramping from 25-40
Xsec is basically on X seconds, off 3 seconds, ramping from 35-100
Feed denotes 20% the whole time. this is when my autofeeder turns on to feed pellets 4 times a day
my goal was to have different patterns hit throughout the day constantly. and the gaps of almost no flow are intentional.